Product Details:
| Rated Current | 800 A |
| Poles | 3 Pole |
| Breaking Capacity | 42 kA |
| Rated Voltage | 415 V |
| Trip Unit | Electronic |
| Operation | Manual |
| Rated Frequency | 50 Hz |
| Series | 3WT |
ACB: 3WJ
• Conforms to IEC 60947-2
• Rated current - 800A to 4000A
• Mechanical contact erosion indicator
• I cu = Ics = Icw(1s) for complete range
• Integrated LCD display and Online test facility
• Breaking capacity upto 55kA
• Ready to close mechanism for safe operation
Standard breaking capacity, 440 VAC Icu = Ics = Icw(1s) Microprocessor based trip unit ETU360WJ: LSING1) + Display
ETU350WJ: LSI + Display
Microprocessor based trip unit ETU360WJ: LSING1) + Display
Product Details:
| Minimum Order Quantity | 1 Piece |
| Rated Current | 630 A |
| Poles | 3 Pole |
| Breaking Capacity | 66 KA |
| Rated Voltage | 415 V |
| Trip Unit | Electronic |
| Operation | Manual |
| Rated Frequency | 50 Hz |
| Series | 3WT |
| Protection | Overload |
ACB: SENTRON 3WTPlus
• Conforms to IEC 60947-2
• Rated current - 630A to 4000A
• Uimp = 12kV
• Integrated communication & metering option • Easy parameterization and diagnostics with Powerconfig
• Mechanical contact erosion indicator • Fully rated upto 50°C
• Integrated LCD display and Online test facility • Variants available for 690V AC applications
Standard breaking capacity, 500VAC Ics = 100% Icu
Microprocessor based trip unit ETU37WT: LSING1) + Display
Microprocessor based Trip Units ETU35WT: LSI + Display 5 Reduce 865.- 5 Reduce 865.- For Non-Automatic ACBs please deduct R 1965/- from the LPs of the ACBs marked l. For type nos. of Non-Automatic ACBs please contact your nearest Siemens Sales Office L: Overload protection S: Delayed Short Circuit protection I: Short circuit protection G: Ground fault protection1) N: Neutral protection1) Standard accessories included for electrical ACB (EDO/EF) = Motor operated mechanism, with mechanical and electrical closing, motor and closing solenoid of 220‑240VAC/DC and shunt release of 220-240V AC/DC. 1) Current transformer for N-conductor shall be ordered separately for 3P ACB with Earth Fault and Neutral Conductor Protection. 2) Standard Accessories included for draw out type ACB (EDO/MDO) = Safety shutter, sealing cap over Off button, door sealing frame, trip unit transparent cover, trip signaling contact, ready to close signaling contact, auxiliary contacts 2NO+ 2NC 3) Standard accessories included for fixed type ACB (EF/MF) = Door sealing frame, trip unit transparent cover, trip signaling contact, ready to close signaling contact, auxiliary contacts 2NO+2NC Note: Please contact your nearest Siemens Sales Office for information on prices of 4000A ACB.
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Rated Current | 630 A |
| Poles | 3 Pole |
| Breaking Capacity | 66 KA |
| Rated Voltage | 500 V |
| Trip Unit | Electronic |
| Operation | Manual |
| Rated Frequency | 50 Hz |
| Series | 3WT |
| Protection | Short Circuit |
ACB: SENTRON 3WTPlus
• Conforms to IEC 60947-2
• Rated current - 630A to 4000A
• Uimp = 12kV
• Integrated communication & metering option • Easy parameterization and diagnostics with Powerconfig
• Mechanical contact erosion indicator • Fully rated upto 50°C
• Integrated LCD display and Online test facility • Variants available for 690V AC applications
Standard breaking capacity, 500VAC Ics = 100% Icu
Microprocessor based trip unit ETU37WT: LSING1) + Display
Microprocessor based Trip Units ETU35WT: LSI + Display 5 Reduce 865.- 5 Reduce 865.- For Non-Automatic ACBs please deduct R 1965/- from the LPs of the ACBs marked l. For type nos. of Non-Automatic ACBs please contact your nearest Siemens Sales Office L: Overload protection S: Delayed Short Circuit protection I: Short circuit protection G: Ground fault protection1) N: Neutral protection1) Standard accessories included for electrical ACB (EDO/EF) = Motor operated mechanism, with mechanical and electrical closing, motor and closing solenoid of 220‑240VAC/DC and shunt release of 220-240V AC/DC. 1) Current transformer for N-conductor shall be ordered separately for 3P ACB with Earth Fault and Neutral Conductor Protection. 2) Standard Accessories included for draw out type ACB (EDO/MDO) = Safety shutter, sealing cap over Off button, door sealing frame, trip unit transparent cover, trip signaling contact, ready to close signaling contact, auxiliary contacts 2NO+ 2NC 3) Standard accessories included for fixed type ACB (EF/MF) = Door sealing frame, trip unit transparent cover, trip signaling contact, ready to close signaling contact, auxiliary contacts 2NO+2NC Note: Please contact your nearest Siemens Sales Office for information on prices of 4000A ACB.
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Rated Current | 630 A |
| Poles | 3 Pole |
| Breaking Capacity | 55 kA |
| Rated Voltage | 500 V |
| Trip Unit | Electronic |
| Operation | Manual |
| Rated Frequency | 50 Hz |
| Series | 3WT |
| Protection | Short Circuit |
ACB: SENTRON 3WTPlus
• Conforms to IEC 60947-2
• Rated current - 630A to 4000A
• Uimp = 12kV
• Integrated communication & metering option • Easy parameterization and diagnostics with Powerconfig
• Mechanical contact erosion indicator • Fully rated upto 50°C
• Integrated LCD display and Online test facility • Variants available for 690V AC applications
Standard breaking capacity, 500VAC Ics = 100% Icu
Microprocessor based trip unit ETU37WT: LSING1) + Display
Microprocessor based Trip Units ETU35WT: LSI + Display 5 Reduce 865.- 5 Reduce 865.- For Non-Automatic ACBs please deduct R 1965/- from the LPs of the ACBs marked l. For type nos. of Non-Automatic ACBs please contact your nearest Siemens Sales Office L: Overload protection S: Delayed Short Circuit protection I: Short circuit protection G: Ground fault protection1) N: Neutral protection1) Standard accessories included for electrical ACB (EDO/EF) = Motor operated mechanism, with mechanical and electrical closing, motor and closing solenoid of 220‑240VAC/DC and shunt release of 220-240V AC/DC. 1) Current transformer for N-conductor shall be ordered separately for 3P ACB with Earth Fault and Neutral Conductor Protection. 2) Standard Accessories included for draw out type ACB (EDO/MDO) = Safety shutter, sealing cap over Off button, door sealing frame, trip unit transparent cover, trip signaling contact, ready to close signaling contact, auxiliary contacts 2NO+ 2NC 3) Standard accessories included for fixed type ACB (EF/MF) = Door sealing frame, trip unit transparent cover, trip signaling contact, ready to close signaling contact, auxiliary contacts 2NO+2NC Note: Please contact your nearest Siemens Sales Office for information on prices of 4000A ACB.
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Rated Current | 630 A |
| Poles | 3 Pole |
| Breaking Capacity | 55 kA |
| Trip Unit | Electronic |
| Operation | Manual |
| Rated Frequency | 50 Hz |
| Series | 3WT |
| Protection | Short Circuit, Overload |
ACB: SENTRON 3WTPlus
• Conforms to IEC 60947-2
• Rated current - 630A to 4000A
• Uimp = 12kV
• Integrated communication & metering option • Easy parameterization and diagnostics with Powerconfig
• Mechanical contact erosion indicator • Fully rated upto 50°C
• Integrated LCD display and Online test facility • Variants available for 690V AC applications
Standard breaking capacity, 500VAC Ics = 100% Icu
Microprocessor based trip unit ETU37WT: LSING1) + Display
Microprocessor based Trip Units ETU35WT: LSI + Display 5 Reduce 865.- 5 Reduce 865.- For Non-Automatic ACBs please deduct R 1965/- from the LPs of the ACBs marked l. For type nos. of Non-Automatic ACBs please contact your nearest Siemens Sales Office L: Overload protection S: Delayed Short Circuit protection I: Short circuit protection G: Ground fault protection1) N: Neutral protection1) Standard accessories included for electrical ACB (EDO/EF) = Motor operated mechanism, with mechanical and electrical closing, motor and closing solenoid of 220‑240VAC/DC and shunt release of 220-240V AC/DC. 1) Current transformer for N-conductor shall be ordered separately for 3P ACB with Earth Fault and Neutral Conductor Protection. 2) Standard Accessories included for draw out type ACB (EDO/MDO) = Safety shutter, sealing cap over Off button, door sealing frame, trip unit transparent cover, trip signaling contact, ready to close signaling contact, auxiliary contacts 2NO+ 2NC 3) Standard accessories included for fixed type ACB (EF/MF) = Door sealing frame, trip unit transparent cover, trip signaling contact, ready to close signaling contact, auxiliary contacts 2NO+2NC Note: Please contact your nearest Siemens Sales Office for information on prices of 4000A ACB.
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Rated Current | 1250 A |
| Poles | 3 Pole |
| Breaking Capacity | 66KA |
| Rated Voltage | 500 V |
| Trip Unit | Electronic |
| Operation | Manual |
| Series | 3WT |
| Protection | Overload |
ACB: SENTRON 3WTPlus
• Conforms to IEC 60947-2
• Rated current - 630A to 4000A
• Uimp = 12kV
• Integrated communication & metering option • Easy parameterization and diagnostics with Powerconfig
• Mechanical contact erosion indicator • Fully rated upto 50°C
• Integrated LCD display and Online test facility • Variants available for 690V AC applications
Standard breaking capacity, 500VAC Ics = 100% Icu
Microprocessor based trip unit ETU37WT: LSING1) + Display
Microprocessor based Trip Units ETU35WT: LSI + Display 5 Reduce 865.- 5 Reduce 865.- For Non-Automatic ACBs please deduct R 1965/- from the LPs of the ACBs marked l. For type nos. of Non-Automatic ACBs please contact your nearest Siemens Sales Office L: Overload protection S: Delayed Short Circuit protection I: Short circuit protection G: Ground fault protection1) N: Neutral protection1) Standard accessories included for electrical ACB (EDO/EF) = Motor operated mechanism, with mechanical and electrical closing, motor and closing solenoid of 220‑240VAC/DC and shunt release of 220-240V AC/DC. 1) Current transformer for N-conductor shall be ordered separately for 3P ACB with Earth Fault and Neutral Conductor Protection. 2) Standard Accessories included for draw out type ACB (EDO/MDO) = Safety shutter, sealing cap over Off button, door sealing frame, trip unit transparent cover, trip signaling contact, ready to close signaling contact, auxiliary contacts 2NO+ 2NC 3) Standard accessories included for fixed type ACB (EF/MF) = Door sealing frame, trip unit transparent cover, trip signaling contact, ready to close signaling contact, auxiliary contacts 2NO+2NC Note: Please contact your nearest Siemens Sales Office for information on prices of 4000A ACB.
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Rated Current | 1600 A |
| Poles | 3 Pole |
| Breaking Capacity | 66 KA |
| Rated Voltage | 500 V |
| Trip Unit | Electronic |
| Operation | Manual |
| Rated Frequency | 50 Hz |
| Series | 3WT |
| Protection | Overload |
ACB: SENTRON 3WTPlus
• Conforms to IEC 60947-2
• Rated current - 630A to 4000A
• Uimp = 12kV
• Integrated communication & metering option • Easy parameterization and diagnostics with Powerconfig
• Mechanical contact erosion indicator • Fully rated upto 50°C
• Integrated LCD display and Online test facility • Variants available for 690V AC applications
Standard breaking capacity, 500VAC Ics = 100% Icu
Microprocessor based trip unit ETU37WT: LSING1) + Display
Microprocessor based Trip Units ETU35WT: LSI + Display 5 Reduce 865.- 5 Reduce 865.- For Non-Automatic ACBs please deduct R 1965/- from the LPs of the ACBs marked l. For type nos. of Non-Automatic ACBs please contact your nearest Siemens Sales Office L: Overload protection S: Delayed Short Circuit protection I: Short circuit protection G: Ground fault protection1) N: Neutral protection1) Standard accessories included for electrical ACB (EDO/EF) = Motor operated mechanism, with mechanical and electrical closing, motor and closing solenoid of 220‑240VAC/DC and shunt release of 220-240V AC/DC. 1) Current transformer for N-conductor shall be ordered separately for 3P ACB with Earth Fault and Neutral Conductor Protection. 2) Standard Accessories included for draw out type ACB (EDO/MDO) = Safety shutter, sealing cap over Off button, door sealing frame, trip unit transparent cover, trip signaling contact, ready to close signaling contact, auxiliary contacts 2NO+ 2NC 3) Standard accessories included for fixed type ACB (EF/MF) = Door sealing frame, trip unit transparent cover, trip signaling contact, ready to close signaling contact, auxiliary contacts 2NO+2NC Note: Please contact your nearest Siemens Sales Office for information on prices of 4000A ACB.
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Rated Current | 2000 A |
| Poles | 3 Pole |
| Breaking Capacity | 66KA |
| Rated Voltage | 500 V |
| Trip Unit | Electronic |
| Operation | Manual |
| Series | 3WT |
| Protection | Overload, Short Circuit |
ACB: SENTRON 3WTPlus
• Conforms to IEC 60947-2
• Rated current - 630A to 4000A
• Uimp = 12kV
• Integrated communication & metering option • Easy parameterization and diagnostics with Powerconfig
• Mechanical contact erosion indicator • Fully rated upto 50°C
• Integrated LCD display and Online test facility • Variants available for 690V AC applications
Standard breaking capacity, 500VAC Ics = 100% Icu
Microprocessor based trip unit ETU37WT: LSING1) + Display
Microprocessor based Trip Units ETU35WT: LSI + Display 5 Reduce 865.- 5 Reduce 865.- For Non-Automatic ACBs please deduct R 1965/- from the LPs of the ACBs marked l. For type nos. of Non-Automatic ACBs please contact your nearest Siemens Sales Office L: Overload protection S: Delayed Short Circuit protection I: Short circuit protection G: Ground fault protection1) N: Neutral protection1) Standard accessories included for electrical ACB (EDO/EF) = Motor operated mechanism, with mechanical and electrical closing, motor and closing solenoid of 220‑240VAC/DC and shunt release of 220-240V AC/DC. 1) Current transformer for N-conductor shall be ordered separately for 3P ACB with Earth Fault and Neutral Conductor Protection. 2) Standard Accessories included for draw out type ACB (EDO/MDO) = Safety shutter, sealing cap over Off button, door sealing frame, trip unit transparent cover, trip signaling contact, ready to close signaling contact, auxiliary contacts 2NO+ 2NC 3) Standard accessories included for fixed type ACB (EF/MF) = Door sealing frame, trip unit transparent cover, trip signaling contact, ready to close signaling contact, auxiliary contacts 2NO+2NC Note: Please contact your nearest Siemens Sales Office for information on prices of 4000A ACB.
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Rated Current | 2000 A |
| Poles | 3 Pole |
| Breaking Capacity | 66 KA |
| Rated Voltage | 500 V |
| Trip Unit | Electronic |
| Operation | Manual |
| Rated Frequency | 50 Hz |
| Series | 3WT |
| Protection | Overload |
ACB: SENTRON 3WTPlus
• Conforms to IEC 60947-2
• Rated current - 630A to 4000A
• Uimp = 12kV
• Integrated communication & metering option • Easy parameterization and diagnostics with Powerconfig
• Mechanical contact erosion indicator • Fully rated upto 50°C
• Integrated LCD display and Online test facility • Variants available for 690V AC applications
Standard breaking capacity, 500VAC Ics = 100% Icu
Microprocessor based trip unit ETU37WT: LSING1) + Display
Microprocessor based Trip Units ETU35WT: LSI + Display 5 Reduce 865.- 5 Reduce 865.- For Non-Automatic ACBs please deduct R 1965/- from the LPs of the ACBs marked l. For type nos. of Non-Automatic ACBs please contact your nearest Siemens Sales Office L: Overload protection S: Delayed Short Circuit protection I: Short circuit protection G: Ground fault protection1) N: Neutral protection1) Standard accessories included for electrical ACB (EDO/EF) = Motor operated mechanism, with mechanical and electrical closing, motor and closing solenoid of 220‑240VAC/DC and shunt release of 220-240V AC/DC. 1) Current transformer for N-conductor shall be ordered separately for 3P ACB with Earth Fault and Neutral Conductor Protection. 2) Standard Accessories included for draw out type ACB (EDO/MDO) = Safety shutter, sealing cap over Off button, door sealing frame, trip unit transparent cover, trip signaling contact, ready to close signaling contact, auxiliary contacts 2NO+ 2NC 3) Standard accessories included for fixed type ACB (EF/MF) = Door sealing frame, trip unit transparent cover, trip signaling contact, ready to close signaling contact, auxiliary contacts 2NO+2NC Note: Please contact your nearest Siemens Sales Office for information on prices of 4000A ACB.
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Rated Current | 630 A |
| Poles | 3 Pole |
| Breaking Capacity | 66 KA |
| Rated Voltage | 500 V |
| Trip Unit | Electronic |
| Operation | Manual |
| Rated Frequency | 50/60 Hz |
| Series | 3WT |
| Protection | Short Circuit |
ACB: SENTRON 3WTPlus
• Conforms to IEC 60947-2
• Rated current - 630A to 4000A
• Uimp = 12kV
• Integrated communication & metering option • Easy parameterization and diagnostics with Powerconfig
• Mechanical contact erosion indicator • Fully rated upto 50°C
• Integrated LCD display and Online test facility • Variants available for 690V AC applications
Standard breaking capacity, 500VAC Ics = 100% Icu
Microprocessor based trip unit ETU37WT: LSING1) + Display
Microprocessor based Trip Units ETU35WT: LSI + Display 5 Reduce 865.- 5 Reduce 865.- For Non-Automatic ACBs please deduct R 1965/- from the LPs of the ACBs marked l. For type nos. of Non-Automatic ACBs please contact your nearest Siemens Sales Office L: Overload protection S: Delayed Short Circuit protection I: Short circuit protection G: Ground fault protection1) N: Neutral protection1) Standard accessories included for electrical ACB (EDO/EF) = Motor operated mechanism, with mechanical and electrical closing, motor and closing solenoid of 220‑240VAC/DC and shunt release of 220-240V AC/DC. 1) Current transformer for N-conductor shall be ordered separately for 3P ACB with Earth Fault and Neutral Conductor Protection. 2) Standard Accessories included for draw out type ACB (EDO/MDO) = Safety shutter, sealing cap over Off button, door sealing frame, trip unit transparent cover, trip signaling contact, ready to close signaling contact, auxiliary contacts 2NO+ 2NC 3) Standard accessories included for fixed type ACB (EF/MF) = Door sealing frame, trip unit transparent cover, trip signaling contact, ready to close signaling contact, auxiliary contacts 2NO+2NC Note: Please contact your nearest Siemens Sales Office for information on prices of 4000A ACB.
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Rated Current | 630 A |
| Poles | 3 Pole |
| Breaking Capacity | 66KA |
| Rated Voltage | 500 V |
| Trip Unit | Electronic |
| Operation | Manual |
| Rated Frequency | 50/60 Hz |
| Series | 3WT |
| Protection | Overload |
ACB: SENTRON 3WTPlus
• Conforms to IEC 60947-2
• Rated current - 630A to 4000A
• Uimp = 12kV
• Integrated communication & metering option • Easy parameterization and diagnostics with Powerconfig
• Mechanical contact erosion indicator • Fully rated upto 50°C
• Integrated LCD display and Online test facility • Variants available for 690V AC applications
Standard breaking capacity, 500VAC Ics = 100% Icu
Microprocessor based trip unit ETU37WT: LSING1) + Display
Microprocessor based Trip Units ETU35WT: LSI + Display 5 Reduce 865.- 5 Reduce 865.- For Non-Automatic ACBs please deduct R 1965/- from the LPs of the ACBs marked l. For type nos. of Non-Automatic ACBs please contact your nearest Siemens Sales Office L: Overload protection S: Delayed Short Circuit protection I: Short circuit protection G: Ground fault protection1) N: Neutral protection1) Standard accessories included for electrical ACB (EDO/EF) = Motor operated mechanism, with mechanical and electrical closing, motor and closing solenoid of 220‑240VAC/DC and shunt release of 220-240V AC/DC. 1) Current transformer for N-conductor shall be ordered separately for 3P ACB with Earth Fault and Neutral Conductor Protection. 2) Standard Accessories included for draw out type ACB (EDO/MDO) = Safety shutter, sealing cap over Off button, door sealing frame, trip unit transparent cover, trip signaling contact, ready to close signaling contact, auxiliary contacts 2NO+ 2NC 3) Standard accessories included for fixed type ACB (EF/MF) = Door sealing frame, trip unit transparent cover, trip signaling contact, ready to close signaling contact, auxiliary contacts 2NO+2NC Note: Please contact your nearest Siemens Sales Office for information on prices of 4000A ACB.
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Rated Current | 1000 A |
| Poles | 4 Pole |
| Breaking Capacity | 66KA |
| Rated Voltage | 500 V |
| Trip Unit | Electronic |
| Operation | Manual |
| Rated Frequency | 50/60 Hz |
| Series | 3WT |
| Protection | Overload |
ACB: SENTRON 3WTPlus
• Conforms to IEC 60947-2
• Rated current - 630A to 4000A
• Uimp = 12kV
• Integrated communication & metering option • Easy parameterization and diagnostics with Powerconfig
• Mechanical contact erosion indicator • Fully rated upto 50°C
• Integrated LCD display and Online test facility • Variants available for 690V AC applications
Standard breaking capacity, 500VAC Ics = 100% Icu
Microprocessor based trip unit ETU37WT: LSING1) + Display
Microprocessor based Trip Units ETU35WT: LSI + Display 5 Reduce 865.- 5 Reduce 865.- For Non-Automatic ACBs please deduct R 1965/- from the LPs of the ACBs marked l. For type nos. of Non-Automatic ACBs please contact your nearest Siemens Sales Office L: Overload protection S: Delayed Short Circuit protection I: Short circuit protection G: Ground fault protection1) N: Neutral protection1) Standard accessories included for electrical ACB (EDO/EF) = Motor operated mechanism, with mechanical and electrical closing, motor and closing solenoid of 220‑240VAC/DC and shunt release of 220-240V AC/DC. 1) Current transformer for N-conductor shall be ordered separately for 3P ACB with Earth Fault and Neutral Conductor Protection. 2) Standard Accessories included for draw out type ACB (EDO/MDO) = Safety shutter, sealing cap over Off button, door sealing frame, trip unit transparent cover, trip signaling contact, ready to close signaling contact, auxiliary contacts 2NO+ 2NC 3) Standard accessories included for fixed type ACB (EF/MF) = Door sealing frame, trip unit transparent cover, trip signaling contact, ready to close signaling contact, auxiliary contacts 2NO+2NC Note: Please contact your nearest Siemens Sales Office for information on prices of 4000A ACB.
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Rated Current | 1000 A |
| Poles | 4 Pole |
| Breaking Capacity | 66 ka |
| Rated Voltage | 500 V |
| Trip Unit | Electronic |
| Operation | Manual |
| Rated Frequency | 50/60 Hz |
| Series | 3WT |
| Protection | Short Circuit |
ACB: SENTRON 3WTPlus
• Conforms to IEC 60947-2
• Rated current - 630A to 4000A
• Uimp = 12kV
• Integrated communication & metering option • Easy parameterization and diagnostics with Powerconfig
• Mechanical contact erosion indicator • Fully rated upto 50°C
• Integrated LCD display and Online test facility • Variants available for 690V AC applications
Standard breaking capacity, 500VAC Ics = 100% Icu
Microprocessor based trip unit ETU37WT: LSING1) + Display
Microprocessor based Trip Units ETU35WT: LSI + Display 5 Reduce 865.- 5 Reduce 865.- For Non-Automatic ACBs please deduct R 1965/- from the LPs of the ACBs marked l. For type nos. of Non-Automatic ACBs please contact your nearest Siemens Sales Office L: Overload protection S: Delayed Short Circuit protection I: Short circuit protection G: Ground fault protection1) N: Neutral protection1) Standard accessories included for electrical ACB (EDO/EF) = Motor operated mechanism, with mechanical and electrical closing, motor and closing solenoid of 220‑240VAC/DC and shunt release of 220-240V AC/DC. 1) Current transformer for N-conductor shall be ordered separately for 3P ACB with Earth Fault and Neutral Conductor Protection. 2) Standard Accessories included for draw out type ACB (EDO/MDO) = Safety shutter, sealing cap over Off button, door sealing frame, trip unit transparent cover, trip signaling contact, ready to close signaling contact, auxiliary contacts 2NO+ 2NC 3) Standard accessories included for fixed type ACB (EF/MF) = Door sealing frame, trip unit transparent cover, trip signaling contact, ready to close signaling contact, auxiliary contacts 2NO+2NC Note: Please contact your nearest Siemens Sales Office for information on prices of 4000A ACB.
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Rated Current | 1250 A |
| Poles | 4 Pole |
| Breaking Capacity | 66 KA |
| Rated Voltage | 500 V |
| Trip Unit | Electronic |
| Operation | Manual |
| Rated Frequency | 50/60 Hz |
| Series | 3WT |
| Protection | Overload |
ACB: SENTRON 3WTPlus
• Conforms to IEC 60947-2
• Rated current - 630A to 4000A
• Uimp = 12kV
• Integrated communication & metering option • Easy parameterization and diagnostics with Powerconfig
• Mechanical contact erosion indicator • Fully rated upto 50°C
• Integrated LCD display and Online test facility • Variants available for 690V AC applications
Standard breaking capacity, 500VAC Ics = 100% Icu
Microprocessor based trip unit ETU37WT: LSING1) + Display
Microprocessor based Trip Units ETU35WT: LSI + Display 5 Reduce 865.- 5 Reduce 865.- For Non-Automatic ACBs please deduct R 1965/- from the LPs of the ACBs marked l. For type nos. of Non-Automatic ACBs please contact your nearest Siemens Sales Office L: Overload protection S: Delayed Short Circuit protection I: Short circuit protection G: Ground fault protection1) N: Neutral protection1) Standard accessories included for electrical ACB (EDO/EF) = Motor operated mechanism, with mechanical and electrical closing, motor and closing solenoid of 220‑240VAC/DC and shunt release of 220-240V AC/DC. 1) Current transformer for N-conductor shall be ordered separately for 3P ACB with Earth Fault and Neutral Conductor Protection. 2) Standard Accessories included for draw out type ACB (EDO/MDO) = Safety shutter, sealing cap over Off button, door sealing frame, trip unit transparent cover, trip signaling contact, ready to close signaling contact, auxiliary contacts 2NO+ 2NC 3) Standard accessories included for fixed type ACB (EF/MF) = Door sealing frame, trip unit transparent cover, trip signaling contact, ready to close signaling contact, auxiliary contacts 2NO+2NC Note: Please contact your nearest Siemens Sales Office for information on prices of 4000A ACB.
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Rated Current | 1250 A |
| Poles | 3 Pole |
| Breaking Capacity | 66 KA |
| Rated Voltage | 500 V |
| Trip Unit | Electronic |
| Operation | Manual |
| Rated Frequency | 50 Hz |
| Series | 3WT |
| Protection | Overload |
ACB: SENTRON 3WTPlus
• Conforms to IEC 60947-2
• Rated current - 630A to 4000A
• Uimp = 12kV
• Integrated communication & metering option • Easy parameterization and diagnostics with Powerconfig
• Mechanical contact erosion indicator • Fully rated upto 50°C
• Integrated LCD display and Online test facility • Variants available for 690V AC applications
Standard breaking capacity, 500VAC Ics = 100% Icu
Microprocessor based trip unit ETU37WT: LSING1) + Display
Microprocessor based Trip Units ETU35WT: LSI + Display 5 Reduce 865.- 5 Reduce 865.- For Non-Automatic ACBs please deduct R 1965/- from the LPs of the ACBs marked l. For type nos. of Non-Automatic ACBs please contact your nearest Siemens Sales Office L: Overload protection S: Delayed Short Circuit protection I: Short circuit protection G: Ground fault protection1) N: Neutral protection1) Standard accessories included for electrical ACB (EDO/EF) = Motor operated mechanism, with mechanical and electrical closing, motor and closing solenoid of 220‑240VAC/DC and shunt release of 220-240V AC/DC. 1) Current transformer for N-conductor shall be ordered separately for 3P ACB with Earth Fault and Neutral Conductor Protection. 2) Standard Accessories included for draw out type ACB (EDO/MDO) = Safety shutter, sealing cap over Off button, door sealing frame, trip unit transparent cover, trip signaling contact, ready to close signaling contact, auxiliary contacts 2NO+ 2NC 3) Standard accessories included for fixed type ACB (EF/MF) = Door sealing frame, trip unit transparent cover, trip signaling contact, ready to close signaling contact, auxiliary contacts 2NO+2NC Note: Please contact your nearest Siemens Sales Office for information on prices of 4000A ACB.
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Rated Current | 1600 A |
| Poles | 3 Pole |
| Breaking Capacity | 66KA |
| Rated Voltage | 500 V |
| Trip Unit | Electronic |
| Operation | Manual |
| Rated Frequency | 50 Hz |
| Series | 3WT |
| Protection | Short Circuit |
ACB: SENTRON 3WTPlus
• Conforms to IEC 60947-2
• Rated current - 630A to 4000A
• Uimp = 12kV
• Integrated communication & metering option • Easy parameterization and diagnostics with Powerconfig
• Mechanical contact erosion indicator • Fully rated upto 50°C
• Integrated LCD display and Online test facility • Variants available for 690V AC applications
Standard breaking capacity, 500VAC Ics = 100% Icu
Microprocessor based trip unit ETU37WT: LSING1) + Display
Microprocessor based Trip Units ETU35WT: LSI + Display 5 Reduce 865.- 5 Reduce 865.- For Non-Automatic ACBs please deduct R 1965/- from the LPs of the ACBs marked l. For type nos. of Non-Automatic ACBs please contact your nearest Siemens Sales Office L: Overload protection S: Delayed Short Circuit protection I: Short circuit protection G: Ground fault protection1) N: Neutral protection1) Standard accessories included for electrical ACB (EDO/EF) = Motor operated mechanism, with mechanical and electrical closing, motor and closing solenoid of 220‑240VAC/DC and shunt release of 220-240V AC/DC. 1) Current transformer for N-conductor shall be ordered separately for 3P ACB with Earth Fault and Neutral Conductor Protection. 2) Standard Accessories included for draw out type ACB (EDO/MDO) = Safety shutter, sealing cap over Off button, door sealing frame, trip unit transparent cover, trip signaling contact, ready to close signaling contact, auxiliary contacts 2NO+ 2NC 3) Standard accessories included for fixed type ACB (EF/MF) = Door sealing frame, trip unit transparent cover, trip signaling contact, ready to close signaling contact, auxiliary contacts 2NO+2NC Note: Please contact your nearest Siemens Sales Office for information on prices of 4000A ACB.
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Rated Current | 2000 A |
| Poles | 3 Pole |
| Breaking Capacity | 66KA |
| Rated Voltage | 500 V |
| Trip Unit | Electronic |
| Operation | Manual |
| Rated Frequency | 50 Hz |
| Series | 3WT |
| Protection | Short Circuit |
ACB: SENTRON 3WTPlus
• Conforms to IEC 60947-2
• Rated current - 630A to 4000A
• Uimp = 12kV
• Integrated communication & metering option • Easy parameterization and diagnostics with Powerconfig
• Mechanical contact erosion indicator • Fully rated upto 50°C
• Integrated LCD display and Online test facility • Variants available for 690V AC applications
Standard breaking capacity, 500VAC Ics = 100% Icu
Microprocessor based trip unit ETU37WT: LSING1) + Display
Microprocessor based Trip Units ETU35WT: LSI + Display 5 Reduce 865.- 5 Reduce 865.- For Non-Automatic ACBs please deduct R 1965/- from the LPs of the ACBs marked l. For type nos. of Non-Automatic ACBs please contact your nearest Siemens Sales Office L: Overload protection S: Delayed Short Circuit protection I: Short circuit protection G: Ground fault protection1) N: Neutral protection1) Standard accessories included for electrical ACB (EDO/EF) = Motor operated mechanism, with mechanical and electrical closing, motor and closing solenoid of 220‑240VAC/DC and shunt release of 220-240V AC/DC. 1) Current transformer for N-conductor shall be ordered separately for 3P ACB with Earth Fault and Neutral Conductor Protection. 2) Standard Accessories included for draw out type ACB (EDO/MDO) = Safety shutter, sealing cap over Off button, door sealing frame, trip unit transparent cover, trip signaling contact, ready to close signaling contact, auxiliary contacts 2NO+ 2NC 3) Standard accessories included for fixed type ACB (EF/MF) = Door sealing frame, trip unit transparent cover, trip signaling contact, ready to close signaling contact, auxiliary contacts 2NO+2NC Note: Please contact your nearest Siemens Sales Office for information on prices of 4000A ACB.
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Rated Current | 2500 A |
| Poles | 3 Pole |
| Breaking Capacity | 55 kA |
| Rated Voltage | 500 V |
| Trip Unit | Electronic |
| Operation | Manual |
| Rated Frequency | 50 Hz |
| Series | 3WT |
| Protection | Short Circuit, Overload |
ACB: SENTRON 3WTPlus
• Conforms to IEC 60947-2
• Rated current - 630A to 4000A
• Uimp = 12kV
• Integrated communication & metering option • Easy parameterization and diagnostics with Powerconfig
• Mechanical contact erosion indicator • Fully rated upto 50°C
• Integrated LCD display and Online test facility • Variants available for 690V AC applications
Standard breaking capacity, 500VAC Ics = 100% Icu
Microprocessor based trip unit ETU37WT: LSING1) + Display
Microprocessor based Trip Units ETU35WT: LSI + Display 5 Reduce 865.- 5 Reduce 865.- For Non-Automatic ACBs please deduct R 1965/- from the LPs of the ACBs marked l. For type nos. of Non-Automatic ACBs please contact your nearest Siemens Sales Office L: Overload protection S: Delayed Short Circuit protection I: Short circuit protection G: Ground fault protection1) N: Neutral protection1) Standard accessories included for electrical ACB (EDO/EF) = Motor operated mechanism, with mechanical and electrical closing, motor and closing solenoid of 220‑240VAC/DC and shunt release of 220-240V AC/DC. 1) Current transformer for N-conductor shall be ordered separately for 3P ACB with Earth Fault and Neutral Conductor Protection. 2) Standard Accessories included for draw out type ACB (EDO/MDO) = Safety shutter, sealing cap over Off button, door sealing frame, trip unit transparent cover, trip signaling contact, ready to close signaling contact, auxiliary contacts 2NO+ 2NC 3) Standard accessories included for fixed type ACB (EF/MF) = Door sealing frame, trip unit transparent cover, trip signaling contact, ready to close signaling contact, auxiliary contacts 2NO+2NC Note: Please contact your nearest Siemens Sales Office for information on prices of 4000A ACB.
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Rated Current | 3200 A |
| Poles | 3 Pole |
| Breaking Capacity | 66KA |
| Rated Voltage | 500 V |
| Trip Unit | Electronic |
| Operation | Manual |
| Rated Frequency | 50 Hz |
| Series | 3WT |
| Protection | Overload |
ACB: SENTRON 3WTPlus
• Conforms to IEC 60947-2
• Rated current - 630A to 4000A
• Uimp = 12kV
• Integrated communication & metering option • Easy parameterization and diagnostics with Powerconfig
• Mechanical contact erosion indicator • Fully rated upto 50°C
• Integrated LCD display and Online test facility • Variants available for 690V AC applications
Standard breaking capacity, 500VAC Ics = 100% Icu
Microprocessor based trip unit ETU37WT: LSING1) + Display
Microprocessor based Trip Units ETU35WT: LSI + Display 5 Reduce 865.- 5 Reduce 865.- For Non-Automatic ACBs please deduct R 1965/- from the LPs of the ACBs marked l. For type nos. of Non-Automatic ACBs please contact your nearest Siemens Sales Office L: Overload protection S: Delayed Short Circuit protection I: Short circuit protection G: Ground fault protection1) N: Neutral protection1) Standard accessories included for electrical ACB (EDO/EF) = Motor operated mechanism, with mechanical and electrical closing, motor and closing solenoid of 220‑240VAC/DC and shunt release of 220-240V AC/DC. 1) Current transformer for N-conductor shall be ordered separately for 3P ACB with Earth Fault and Neutral Conductor Protection. 2) Standard Accessories included for draw out type ACB (EDO/MDO) = Safety shutter, sealing cap over Off button, door sealing frame, trip unit transparent cover, trip signaling contact, ready to close signaling contact, auxiliary contacts 2NO+ 2NC 3) Standard accessories included for fixed type ACB (EF/MF) = Door sealing frame, trip unit transparent cover, trip signaling contact, ready to close signaling contact, auxiliary contacts 2NO+2NC Note: Please contact your nearest Siemens Sales Office for information on prices of 4000A ACB.
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Rated Current | 800 A |
| Poles | 3 Pole |
| Breaking Capacity | 66 KA |
| Rated Voltage | 500 V |
| Trip Unit | Electronic |
| Operation | Manual |
| Rated Frequency | 50/60 Hz |
| Series | 3WT |
| Protection | Short Circuit, Overload |
ACB: SENTRON 3WTPlus
• Conforms to IEC 60947-2
• Rated current - 630A to 4000A
• Uimp = 12kV
• Integrated communication & metering option • Easy parameterization and diagnostics with Powerconfig
• Mechanical contact erosion indicator • Fully rated upto 50°C
• Integrated LCD display and Online test facility • Variants available for 690V AC applications
Standard breaking capacity, 500VAC Ics = 100% Icu
Microprocessor based trip unit ETU37WT: LSING1) + Display
Microprocessor based Trip Units ETU35WT: LSI + Display 5 Reduce 865.- 5 Reduce 865.- For Non-Automatic ACBs please deduct R 1965/- from the LPs of the ACBs marked l. For type nos. of Non-Automatic ACBs please contact your nearest Siemens Sales Office L: Overload protection S: Delayed Short Circuit protection I: Short circuit protection G: Ground fault protection1) N: Neutral protection1) Standard accessories included for electrical ACB (EDO/EF) = Motor operated mechanism, with mechanical and electrical closing, motor and closing solenoid of 220‑240VAC/DC and shunt release of 220-240V AC/DC. 1) Current transformer for N-conductor shall be ordered separately for 3P ACB with Earth Fault and Neutral Conductor Protection. 2) Standard Accessories included for draw out type ACB (EDO/MDO) = Safety shutter, sealing cap over Off button, door sealing frame, trip unit transparent cover, trip signaling contact, ready to close signaling contact, auxiliary contacts 2NO+ 2NC 3) Standard accessories included for fixed type ACB (EF/MF) = Door sealing frame, trip unit transparent cover, trip signaling contact, ready to close signaling contact, auxiliary contacts 2NO+2NC Note: Please contact your nearest Siemens Sales Office for information on prices of 4000A ACB.
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Rated Current | 800 A |
| Poles | 4 Pole |
| Breaking Capacity | 66 KA |
| Rated Voltage | 500 V |
| Trip Unit | Electronic |
| Operation | Manual |
| Rated Frequency | 50/60 Hz |
| Series | 3WT |
| Protection | Short Circuit |
ACB: SENTRON 3WTPlus
• Conforms to IEC 60947-2
• Rated current - 630A to 4000A
• Uimp = 12kV
• Integrated communication & metering option • Easy parameterization and diagnostics with Powerconfig
• Mechanical contact erosion indicator • Fully rated upto 50°C
• Integrated LCD display and Online test facility • Variants available for 690V AC applications
Standard breaking capacity, 500VAC Ics = 100% Icu
Microprocessor based trip unit ETU37WT: LSING1) + Display
Microprocessor based Trip Units ETU35WT: LSI + Display 5 Reduce 865.- 5 Reduce 865.- For Non-Automatic ACBs please deduct R 1965/- from the LPs of the ACBs marked l. For type nos. of Non-Automatic ACBs please contact your nearest Siemens Sales Office L: Overload protection S: Delayed Short Circuit protection I: Short circuit protection G: Ground fault protection1) N: Neutral protection1) Standard accessories included for electrical ACB (EDO/EF) = Motor operated mechanism, with mechanical and electrical closing, motor and closing solenoid of 220‑240VAC/DC and shunt release of 220-240V AC/DC. 1) Current transformer for N-conductor shall be ordered separately for 3P ACB with Earth Fault and Neutral Conductor Protection. 2) Standard Accessories included for draw out type ACB (EDO/MDO) = Safety shutter, sealing cap over Off button, door sealing frame, trip unit transparent cover, trip signaling contact, ready to close signaling contact, auxiliary contacts 2NO+ 2NC 3) Standard accessories included for fixed type ACB (EF/MF) = Door sealing frame, trip unit transparent cover, trip signaling contact, ready to close signaling contact, auxiliary contacts 2NO+2NC Note: Please contact your nearest Siemens Sales Office for information on prices of 4000A ACB.
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Rated Current | 1250 A |
| Poles | 4 Pole |
| Breaking Capacity | 66 KA |
| Rated Voltage | 500 V |
| Trip Unit | Electronic |
| Operation | Manual |
| Rated Frequency | 50/60 Hz |
| Series | 3WT |
| Protection | Overload |
ACB: SENTRON 3WTPlus
• Conforms to IEC 60947-2
• Rated current - 630A to 4000A
• Uimp = 12kV
• Integrated communication & metering option • Easy parameterization and diagnostics with Powerconfig
• Mechanical contact erosion indicator • Fully rated upto 50°C
• Integrated LCD display and Online test facility • Variants available for 690V AC applications
Standard breaking capacity, 500VAC Ics = 100% Icu
Microprocessor based trip unit ETU37WT: LSING1) + Display
Microprocessor based Trip Units ETU35WT: LSI + Display 5 Reduce 865.- 5 Reduce 865.- For Non-Automatic ACBs please deduct R 1965/- from the LPs of the ACBs marked l. For type nos. of Non-Automatic ACBs please contact your nearest Siemens Sales Office L: Overload protection S: Delayed Short Circuit protection I: Short circuit protection G: Ground fault protection1) N: Neutral protection1) Standard accessories included for electrical ACB (EDO/EF) = Motor operated mechanism, with mechanical and electrical closing, motor and closing solenoid of 220‑240VAC/DC and shunt release of 220-240V AC/DC. 1) Current transformer for N-conductor shall be ordered separately for 3P ACB with Earth Fault and Neutral Conductor Protection. 2) Standard Accessories included for draw out type ACB (EDO/MDO) = Safety shutter, sealing cap over Off button, door sealing frame, trip unit transparent cover, trip signaling contact, ready to close signaling contact, auxiliary contacts 2NO+ 2NC 3) Standard accessories included for fixed type ACB (EF/MF) = Door sealing frame, trip unit transparent cover, trip signaling contact, ready to close signaling contact, auxiliary contacts 2NO+2NC Note: Please contact your nearest Siemens Sales Office for information on prices of 4000A ACB.
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Rated Current | 1600 A |
| Poles | 4 Pole |
| Breaking Capacity | 66 KA |
| Rated Voltage | 500 V |
| Trip Unit | Electronic |
| Operation | Manual |
| Rated Frequency | 50/60 Hz |
| Series | 3WT |
| Protection | Short Circuit |
ACB: SENTRON 3WTPlus
• Conforms to IEC 60947-2
• Rated current - 630A to 4000A
• Uimp = 12kV
• Integrated communication & metering option • Easy parameterization and diagnostics with Powerconfig
• Mechanical contact erosion indicator • Fully rated upto 50°C
• Integrated LCD display and Online test facility • Variants available for 690V AC applications
Standard breaking capacity, 500VAC Ics = 100% Icu
Microprocessor based trip unit ETU37WT: LSING1) + Display
Microprocessor based Trip Units ETU35WT: LSI + Display 5 Reduce 865.- 5 Reduce 865.- For Non-Automatic ACBs please deduct R 1965/- from the LPs of the ACBs marked l. For type nos. of Non-Automatic ACBs please contact your nearest Siemens Sales Office L: Overload protection S: Delayed Short Circuit protection I: Short circuit protection G: Ground fault protection1) N: Neutral protection1) Standard accessories included for electrical ACB (EDO/EF) = Motor operated mechanism, with mechanical and electrical closing, motor and closing solenoid of 220‑240VAC/DC and shunt release of 220-240V AC/DC. 1) Current transformer for N-conductor shall be ordered separately for 3P ACB with Earth Fault and Neutral Conductor Protection. 2) Standard Accessories included for draw out type ACB (EDO/MDO) = Safety shutter, sealing cap over Off button, door sealing frame, trip unit transparent cover, trip signaling contact, ready to close signaling contact, auxiliary contacts 2NO+ 2NC 3) Standard accessories included for fixed type ACB (EF/MF) = Door sealing frame, trip unit transparent cover, trip signaling contact, ready to close signaling contact, auxiliary contacts 2NO+2NC Note: Please contact your nearest Siemens Sales Office for information on prices of 4000A ACB.
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Rated Current | 2000 A |
| Poles | 4 Pole |
| Breaking Capacity | 66KA |
| Rated Voltage | 500 V |
| Trip Unit | Electronic |
| Operation | Manual |
| Rated Frequency | 50/60 Hz |
| Series | 3WT |
| Protection | Overload |
ACB: SENTRON 3WTPlus
• Conforms to IEC 60947-2
• Rated current - 630A to 4000A
• Uimp = 12kV
• Integrated communication & metering option • Easy parameterization and diagnostics with Powerconfig
• Mechanical contact erosion indicator • Fully rated upto 50°C
• Integrated LCD display and Online test facility • Variants available for 690V AC applications
Standard breaking capacity, 500VAC Ics = 100% Icu
Microprocessor based trip unit ETU37WT: LSING1) + Display
Microprocessor based Trip Units ETU35WT: LSI + Display 5 Reduce 865.- 5 Reduce 865.- For Non-Automatic ACBs please deduct R 1965/- from the LPs of the ACBs marked l. For type nos. of Non-Automatic ACBs please contact your nearest Siemens Sales Office L: Overload protection S: Delayed Short Circuit protection I: Short circuit protection G: Ground fault protection1) N: Neutral protection1) Standard accessories included for electrical ACB (EDO/EF) = Motor operated mechanism, with mechanical and electrical closing, motor and closing solenoid of 220‑240VAC/DC and shunt release of 220-240V AC/DC. 1) Current transformer for N-conductor shall be ordered separately for 3P ACB with Earth Fault and Neutral Conductor Protection. 2) Standard Accessories included for draw out type ACB (EDO/MDO) = Safety shutter, sealing cap over Off button, door sealing frame, trip unit transparent cover, trip signaling contact, ready to close signaling contact, auxiliary contacts 2NO+ 2NC 3) Standard accessories included for fixed type ACB (EF/MF) = Door sealing frame, trip unit transparent cover, trip signaling contact, ready to close signaling contact, auxiliary contacts 2NO+2NC Note: Please contact your nearest Siemens Sales Office for information on prices of 4000A ACB.
Additional Information:
Product Details:
| Rated Current | 800 A |
| Poles | 3 Pole |
| Breaking Capacity | 50 kA |
| Rated Voltage | 440 V |
| Trip Unit | Electronic |
| Operation | Manual |
| Rated Frequency | 50 Hz |
| Series | Sirius |
| Protection | Short Circuit |
ACB: 3WJ
• Conforms to IEC 60947-2
• Rated current - 800A to 4000A
• Mechanical contact erosion indicator
• I cu = Ics = Icw(1s) for complete range
• Integrated LCD display and Online test facility
• Breaking capacity upto 55kA
• Ready to close mechanism for safe operation
Standard breaking capacity, 440 VAC Icu = Ics = Icw(1s) Microprocessor based trip unit ETU360WJ: LSING1) + Display
ETU350WJ: LSI + Display
Microprocessor based trip unit ETU360WJ: LSING1) + Display
Product Details:
| Minimum Order Quantity | 1 Piece |
| Rated Current | 3200 A |
| Poles | 3 Pole |
| Breaking Capacity | 55 kA |
| Rated Voltage | 440 V |
| Trip Unit | Electronic |
| Operation | Manual |
| Rated Frequency | 50/60 Hz |
| Series | 3WL |
| Protection | Overload |
ACB: 3WJ
• Conforms to IEC 60947-2
• Rated current - 800A to 4000A
• Mechanical contact erosion indicator
• I cu = Ics = Icw(1s) for complete range
• Integrated LCD display and Online test facility
• Breaking capacity upto 55kA
• Ready to close mechanism for safe operation
Standard breaking capacity, 440 VAC Icu = Ics = Icw(1s) Microprocessor based trip unit ETU360WJ: LSING1) + Display
ETU350WJ: LSI + Display
Microprocessor based trip unit ETU360WJ: LSING1) + Display
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Rated Current | 1600 A |
| Poles | 4 Pole |
| Breaking Capacity | 66KA |
| Rated Voltage | 500 V |
| Trip Unit | Electronic |
| Operation | Manual |
| Rated Frequency | 50/60 Hz |
| Series | 3WT |
| Protection | Overload |
ACB: SENTRON 3WTPlus
• Conforms to IEC 60947-2
• Rated current - 630A to 4000A
• Uimp = 12kV
• Integrated communication & metering option • Easy parameterization and diagnostics with Powerconfig
• Mechanical contact erosion indicator • Fully rated upto 50°C
• Integrated LCD display and Online test facility • Variants available for 690V AC applications
Standard breaking capacity, 500VAC Ics = 100% Icu
Microprocessor based trip unit ETU37WT: LSING1) + Display
Microprocessor based Trip Units ETU35WT: LSI + Display 5 Reduce 865.- 5 Reduce 865.- For Non-Automatic ACBs please deduct R 1965/- from the LPs of the ACBs marked l. For type nos. of Non-Automatic ACBs please contact your nearest Siemens Sales Office L: Overload protection S: Delayed Short Circuit protection I: Short circuit protection G: Ground fault protection1) N: Neutral protection1) Standard accessories included for electrical ACB (EDO/EF) = Motor operated mechanism, with mechanical and electrical closing, motor and closing solenoid of 220‑240VAC/DC and shunt release of 220-240V AC/DC. 1) Current transformer for N-conductor shall be ordered separately for 3P ACB with Earth Fault and Neutral Conductor Protection. 2) Standard Accessories included for draw out type ACB (EDO/MDO) = Safety shutter, sealing cap over Off button, door sealing frame, trip unit transparent cover, trip signaling contact, ready to close signaling contact, auxiliary contacts 2NO+ 2NC 3) Standard accessories included for fixed type ACB (EF/MF) = Door sealing frame, trip unit transparent cover, trip signaling contact, ready to close signaling contact, auxiliary contacts 2NO+2NC Note: Please contact your nearest Siemens Sales Office for information on prices of 4000A ACB.
Additional Information:
Product Details:
| Minimum Order Quantity | 2 Terabyte |
| Rated Current | 630 A |
| Poles | 3 Pole |
| Breaking Capacity | 66 KA |
| Rated Voltage | 500 V |
| Trip Unit | Electronic |
| Operation | Manual |
| Rated Frequency | 50 Hz |
| Series | 3WT |
| Protection | Overload |
ACB: SENTRON 3WTPlus
• Conforms to IEC 60947-2
• Rated current - 630A to 4000A
• Uimp = 12kV
• Integrated communication & metering option • Easy parameterization and diagnostics with Powerconfig
• Mechanical contact erosion indicator • Fully rated upto 50°C
• Integrated LCD display and Online test facility • Variants available for 690V AC applications
Standard breaking capacity, 500VAC Ics = 100% Icu
Microprocessor based trip unit ETU37WT: LSING1) + Display
Microprocessor based Trip Units ETU35WT: LSI + Display 5 Reduce 865.- 5 Reduce 865.- For Non-Automatic ACBs please deduct R 1965/- from the LPs of the ACBs marked l. For type nos. of Non-Automatic ACBs please contact your nearest Siemens Sales Office L: Overload protection S: Delayed Short Circuit protection I: Short circuit protection G: Ground fault protection1) N: Neutral protection1) Standard accessories included for electrical ACB (EDO/EF) = Motor operated mechanism, with mechanical and electrical closing, motor and closing solenoid of 220‑240VAC/DC and shunt release of 220-240V AC/DC. 1) Current transformer for N-conductor shall be ordered separately for 3P ACB with Earth Fault and Neutral Conductor Protection. 2) Standard Accessories included for draw out type ACB (EDO/MDO) = Safety shutter, sealing cap over Off button, door sealing frame, trip unit transparent cover, trip signaling contact, ready to close signaling contact, auxiliary contacts 2NO+ 2NC 3) Standard accessories included for fixed type ACB (EF/MF) = Door sealing frame, trip unit transparent cover, trip signaling contact, ready to close signaling contact, auxiliary contacts 2NO+2NC Note: Please contact your nearest Siemens Sales Office for information on prices of 4000A ACB.
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Rated Current | 3200 A |
| Poles | 3 Pole |
| Breaking Capacity | 66KA |
| Rated Voltage | 500 V |
| Trip Unit | Electronic |
| Operation | Manual |
| Rated Frequency | 50 Hz |
| Series | 3WT |
| Protection | Overload |
ACB: SENTRON 3WTPlus
• Conforms to IEC 60947-2
• Rated current - 630A to 4000A
• Uimp = 12kV
• Integrated communication & metering option • Easy parameterization and diagnostics with Powerconfig
• Mechanical contact erosion indicator • Fully rated upto 50°C
• Integrated LCD display and Online test facility • Variants available for 690V AC applications
Standard breaking capacity, 500VAC Ics = 100% Icu
Microprocessor based trip unit ETU37WT: LSING1) + Display
Microprocessor based Trip Units ETU35WT: LSI + Display 5 Reduce 865.- 5 Reduce 865.- For Non-Automatic ACBs please deduct R 1965/- from the LPs of the ACBs marked l. For type nos. of Non-Automatic ACBs please contact your nearest Siemens Sales Office L: Overload protection S: Delayed Short Circuit protection I: Short circuit protection G: Ground fault protection1) N: Neutral protection1) Standard accessories included for electrical ACB (EDO/EF) = Motor operated mechanism, with mechanical and electrical closing, motor and closing solenoid of 220‑240VAC/DC and shunt release of 220-240V AC/DC. 1) Current transformer for N-conductor shall be ordered separately for 3P ACB with Earth Fault and Neutral Conductor Protection. 2) Standard Accessories included for draw out type ACB (EDO/MDO) = Safety shutter, sealing cap over Off button, door sealing frame, trip unit transparent cover, trip signaling contact, ready to close signaling contact, auxiliary contacts 2NO+ 2NC 3) Standard accessories included for fixed type ACB (EF/MF) = Door sealing frame, trip unit transparent cover, trip signaling contact, ready to close signaling contact, auxiliary contacts 2NO+2NC Note: Please contact your nearest Siemens Sales Office for information on prices of 4000A ACB.
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Rated Current | 800 A |
| Poles | 3 Pole |
| Breaking Capacity | 55 kA |
| Rated Voltage | 440 V |
| Trip Unit | Electronic |
| Operation | Manual |
| Rated Frequency | 50 Hz |
| Series | 3WL |
| Protection | Overload |
ACB: 3WJ
• Conforms to IEC 60947-2
• Rated current - 800A to 4000A
• Mechanical contact erosion indicator
• I cu = Ics = Icw(1s) for complete range
• Integrated LCD display and Online test facility
• Breaking capacity upto 55kA
• Ready to close mechanism for safe operation
Standard breaking capacity, 440 VAC Icu = Ics = Icw(1s) Microprocessor based trip unit ETU360WJ: LSING1) + Display
ETU350WJ: LSI + Display
Microprocessor based trip unit ETU360WJ: LSING1) + Display
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Rated Current | 3200 A |
| Poles | 3 Pole |
| Breaking Capacity | 55 kA |
| Rated Voltage | 440 V |
| Trip Unit | Electronic |
| Operation | Manual |
| Rated Frequency | 50 Hz |
| Series | 3WL |
| Protection | Overload, Under Voltage |
ACB: 3WJ
• Conforms to IEC 60947-2
• Rated current - 800A to 4000A
• Mechanical contact erosion indicator
• I cu = Ics = Icw(1s) for complete range
• Integrated LCD display and Online test facility
• Breaking capacity upto 55kA
• Ready to close mechanism for safe operation
Standard breaking capacity, 440 VAC Icu = Ics = Icw(1s) Microprocessor based trip unit ETU360WJ: LSING1) + Display
ETU350WJ: LSI + Display
Microprocessor based trip unit ETU360WJ: LSING1) + Display
Additional Information: